[Scope of application]
adviceLUNA II
[Information]
If you want to debug CycloneV with adviceLUNA II, please note that some files used in the debugger is not the same depending on the version of H2X600 install kit. As a result, compatibility of projects cannot be maintained when upgrading the version of software, and the following error occurs.
Error No.8014: Unable to set a core configuration setting definition file.
[Workaround]
The workaround varies depending on the version of H2X600 install kit.
- When upgrading to Ver.1.05 from Ver.1.04
⇒Compatibility of project files cannot be maintained. The error occurs. Please create a new project again after the version upgrade.
If you create a new project with AMP configuration, select either one of the following device configuration at the core configuration setting window.
・CycloneV_Cortex-A9MPx2
・CycloneV_Cortex-A9MPx2_ptm - When upgrading to Ver.1.05 from Ver.1.03 or earlier
⇒Compatibility of project files can be maintained.
You can use the current project after the version upgrade. - When upgrading to Ver.1.04 from Ver.1.03 or earlier
⇒Please do not use Ver.1.04. Use Ver.1.05 or later instead.