① Occurs when selecting the YIM folder
・The definition file loaded into the YIM folder is a file for a different series of
programmer.
(For example, the YIM folder itself was created with another series of programmer
and copied beforehand using a memory card reader, etc.)
*There is no compatibility between the definition files and Micom Packs
of the following series:
• NETIMPRESS next / G-NETIMPRESS
• NETIMPRESS air
• NETIMPRESS avant / acorde
*If you select the YIM folder for next with air, you will get "102D: CM SUM CHK ERR".
・The file inside the YIM folder (CM.SYS in the SYSTEM folder) is corrupted.
→Delete the YIM folder causing the error,recreate the YIM folder, and try again.
・Memory card (CF card/SD card) read error.
→Format the SD card, recreate the YIM folder, and try again.
② Error when loading the definition file (.CM)
An attempt was made to load a definition file for a different programmer series.
③ Occurs when copying YIM folders (folder copying from PC to programmer using remote software)
When copying an air-compatible YIM folder using SWX600 (avant/acorde), a CM FORMAT ERR occurs.
*Behavior when copying YIM folders from other series using different software (cannot be used after copying due to incompatibility)
When copying a next-compatible YIM folder using SWX600(avant/acorde), no error occurs.
When copying an avant/acorde-compatible YIM folder using air Connect(air), "122: YIM Folder System Error" occurs.
When copying a next-compatible YIM folder using air Connect(air), no error occurs.
When copying an air-compatible YIM folder using AZ490 (next), no error occurs.
When copying an avant/acorde-compatible YIM folder using AZ490 (next), "122: YIM Folder System Error" occurs.