Target Defintion Program: FRX824, FRX830, FRX830-S10, FRX830-S20, FRX830-S24
1. Meaning of the Error
"S ID NOMATCH ERR" is an error that occurs when ID authentication fails.
2. Causes of the Error and Solutions
* This error occurs because the microcontroller is set to ID authentication mode, and the "Serial Programming ID" set on the microcontroller does not match the "Serial Programming ID" for authentication set in the "YDD file".
* Please check the contents of your YDD file and verify that the correct "Serial Programming ID" is set to match the ID programmed to the microcontroller.
For instructions on setting and changing the Serial Programming ID in the YDD file, please refer to the related articles below.
■Related Article
[avant, acorde] How to Set Up YDD Files (Applicable Model: FRX830)