[Scope of application]
adviceLUNA/ adviceLUNA2
SLX600, SLX603, SLX604, SLX605, SLX620, SLX621, SLX622, SLX623, SLX624,
SLX670, SLX674, SLX680, SLX683, SLX684, SLX685, SLX686, SLX687
S2X600, S2X603,
[Error message]
Following error message is shown at the output window when reopening the project, or after the ICE connection setting is completed when creating a new project.
(example1)
-----------------------------------------------------------------------
* ERROR: No probe is connected or the probe is defective.
* Check the probe connection.
* If you still get the same error, then install the system again.
* Please note that you cannot use microVIEW-PLUS with the models without JTAG probe.
-----------------------------------------------------------------------
(example2)
-----------------------------------------------------------------------
* ERROR: No JATG probe is connected or the probe is defective.
* Check the probe connection.
* Please note that you cannot use microVIEW-PLUS with the models without JTAG probe.
-----------------------------------------------------------------------
[Cause]
This error is shown when MPU system cannot recognize the hardware configuration of advice products. BUSY LED blinks in red when this error occurs.
[Workaround]
If you did not set anything at all after opening the package
You cannot use the advice series products with the factory settings.
Connect the necessary probe to advice product main unit, and install MPU system from APClient.
If you use adviceLUNA2 and OCD probe.
You cannot use adviceLUNA2 setting only OCD probe.
Set OCD probe and flat cable to adviceLUNA2.
If this error is shown after changing the probe configuration
If you are using advice products with the configuration of AP521/xG + H2X600JP, and add H2X600XP for ETM trace newly, then you need to install MPU system from APClient.