[Supported model]
adviceLUNA, adviceLUNA2
[Scope of application]
ARM
[Error message]
ICE Error No.F1B: No sequencer resources of ETM available.
Check ETM resources status with the Config. tab of the ETM Control dialog box.
[Cause]
This error is output when the MPU you are using does not support Sequencer function.
[Workaround]
Choose [MPU] - [ETM Control] from the menu bar of the microVIEW-PLUS.
Check if Sequencer is listed as “Supported” on the [Config.] tab.