[Supported model]
adviceLUNA, adviceLUNA2
[Scope of application]
SLX600, SLX603, SLX604, SLX605, SLX620, SLX621, SLX622, SLX623, SLX624
SLX670, SLX674, SLX680, SLX683, SLX684, SLX685, SLX686, SLX687
S2X600, S2X603,
[Question]
“GetProcAddress Error” occurs. I cannot start microVIEW-PLUS.
What should I do?
[Answer]
This error message is shown when the version of microVIEW-PLUS debugger, which is installed in the host PC and the version of ICE firmware are not matched.
This error message is also shown when it cannot refer to .dll file of debugger.
[Workaround]
(1) Refer to “Installing to ICE” from the link below, and update MPU system by using APClient tool.
(adviceLUNA2 How to upgrade install)
https://www.dts-insight.co.jp/support/support_luna2/?m=VersionUp&item=1
(adviceLUNA How to upgrade install)
https://www.dts-insight.co.jp/support/support_advice/?m=AdviceVersionUp&item=1
(2) If this error message is shown when creating a new project, a file path of MPV file which you chosen at User system connection dialog box may be not correct.
Select MPV file in the \mpv\HLX600 (or folder with model name) in the installed directory (where MViewPLUS.exe has been saved.)
(3) If you cannot solve the problem even after doing above, uninstall microVIEW-PLUS once and install it again.