[Scope of application]
adviceXross, adviceLUNA II, adviceLUNA
[Information]
If you connect ICE by hot plug without turning off the user system power after exiting a system verification debug tool of Xillinx, Xilinx Microprocessor Debugger(XMD), depending on the revision of Vivado Design Suite, a design development environment of Xilinx, you will need to issue the following command from debugger after the hot plug.
For Vivado 2013.4 or earlier
You do not issue a command after connecting adviceLUNA/LUNA II by hot plug.
For Vivado 2014.1 or later
Issue the following command from a command window of debugger after connecting ICE.
mem l dp:0x4=0xf0000000 off
[Notes]
Following error may occur when downloading or performing step if you did not issue the command even though you are using Vivado 2014.1 or later.
ICE Error No.f56: Sticky over run error.